Inhaltstyp
Kategorien
-
Commissioning and maintenance of heat pumps
- /en/research-topics/training-education/training-in-the-field-of-heat-pumps/commissioning-and-maintenance-of-heat-pumps
Commissioning and maintenance of heat pumps Commissioning and maintenance of heat pumps Classroom course This compact refrigeration technology course is aimed at trained heating installers who mainly
-
Planning, installation and maintenance of heat pumps
- /en/research-topics/training-education/training-in-the-field-of-heat-pumps/planning-installation-and-maintenance-of-heat-pumps-1
Planning, installation and maintenance of heat pumps Planning, installation and maintenance of heat pumps In recent years, the extremely versatile heat pump technology has been able to establish itsel
-
Person certification heat pumps
- /en/research-topics/training-education/training-in-the-field-of-heat-pumps/person-certification-heat-pumps
Person certification heat pumps Person certification heat pumps After successfully passing the access examination and meeting further criteria, certification can be applied for in the respective subje
-
Acoustic design for heat pumps
- /en/research-topics/training-education/training-in-the-field-of-heat-pumps/acoustic-design-for-heat-pumps
Acoustic design for heat pumps Acoustic design for heat pumps The low installation costs and small footprint of air-to-water heat pumps are unbeatable compared to other heat source systems. The disadv
-
Methods
- /en/research-topics/thermophysics/methods
Methods The AIT Thermophysics Laboratory has continuously expanded its measurement capabilities over the past 50 years to include extreme temperature conditions. Today, the limits range from liquid ni
-
Additional Devices
- /en/research-topics/thermophysics/methods/additional-devices
Additional Devices Sputter system: Denton Vacuum DESK V Sandblaster: Refert Basic Classic Microscope: Olympus SZX7 Stereo Microscope Lab oven: Memmert UFP 500 (25 to 250°C) Humidity Generator: ProUmid
-
Person certification photovoltaics
- /en/research-topics/training-education/training-in-the-field-of-photovoltaics/person-certification-photovoltaics
Person certification photovoltaics Person certification photovoltaics Certified photovoltaic technician or planner Since the beginning of 2017, personal certification in the field of photovoltaics is
-
Oscillating U-Tube
- /en/research-topics/thermophysics/methods/oscillating-u-tube
Oscillating U-Tube Anton Paar DMA 4500 M Product name: Anton Paar DMA 4500 M Temperature range: 0 to 100 °C Density range: 0 to 3 g/cm 3
-
Knowledge of standards and guidelines
- /en/research-topics/training-education/training-in-the-field-of-photovoltaics/further-courses-in-the-field-of-photovoltaics/knowledge-of-standards-and-guidelines
Knowledge of standards and guidelines Knowledge of standards and guidelines
-
pro:motion
- /en/themen/integrated-mobility-systems/projects/promotion
pro:motion Nachhaltige Mobilität mit technologiebasierten Lösungen durch Zielgruppenorientierung und -motivation Die Forcierung aktiver Mobilitätsformen ist sowohl aus Gründen der Nachhaltigkeit als a
-
STA - Simultaneous Thermal Analysis
- /en/research-topics/thermophysics/methods/sta-simultaneous-thermal-analysis
STA - Simultaneous Thermal Analysis NETZSCH STA 449 F1 Jupiter Temperature range: -120 to 1650 °C Heating rates: 0.1 to 50 K/min Sensors: TGA, TGA-DTA, TGA-DSC Max. sample load: 5000 mg Balance resolu
-
LFA - Laser Flash Analysis
- /en/research-topics/thermophysics/methods/lfa-laser-flash-analysis
LFA - Laser Flash Analysis NETZSCH LFA 467 HyperFlash Temperature range: -100 to 500 °C Pulse energy: up to 10 J Thermal diffusivity: 0.01 to 1000 mm²/s Sample dimension: 6 to 25 mm, square/round shap
-
EGA - Evolved Gas Analysis
- /en/research-topics/thermophysics/methods/ega-evolved-gas-analysis
EGA - Evolved Gas Analysis NETZSCH QMS 403 C Type: quadrupole mass spectrometer Mass range: 1 to 300 u (unified atomic mass unit) Ion source: electron impact, energy 100 eV Detector: Faraday and SEV (
-
DSC - Differential Scanning Calorimetry
- /en/research-topics/thermophysics/methods/dsc-differential-scanning-calorimetry
DSC - Differential Scanning Calorimetry NETZSCH DSC 204 F1 Phoenix Temperature range: -180 to 700 °C Heating rates: 0.001 to 100 K/min Gases: mass flow controlled He / Ar / N 2 / synthetic air Automat
-
DIL - Push Rod Dilatometry
- /en/research-topics/thermophysics/methods/dil-push-rod-dilatometry
DIL - Push Rod Dilatometry NETZSCH DIL 402 Expedis Supreme Temperature range: -180 to 1650 °C Measurement path: ±25 mm Sample length: max. 52 mm Gases: mass flow controlled He Vacuum: rotary vane pump
-
Kinematic Viscometer
- /en/research-topics/thermophysics/methods/kinematic-viscometer
Kinematic Viscometer Anton Paar SVM 3001 Temperature range: -60 °C to +135 °C Viscosity range : 0.2 mm²/s to 30 000 mm²/s Density range : 0.6 g/cm³ to 3 g/cm³ Sample volume : min./typical 1.5 mL / 5 m
-
THB - Transient Hot Bridge
- /en/research-topics/thermophysics/methods/thb-transient-hot-bridge
THB - Transient Hot Bridge LINSEIS THB 100 Temperature range: -15 to 200 °C Thermal conductivity: 0.01 - 100 W/mK Samples: solids, powders, liquids
-
HFM - Heat Flow Meter
- /en/research-topics/thermophysics/methods/hfm-heat-flow-meter
HFM - Heat Flow Meter Heat Flow Meter - HFM Product : NETZSCH HFM 446 Lambda Temperature range : -20 °C to 90 °C Thermal conductivity : up to 2 W/mK Samples : solids, powders
-
Services
- /en/research-topics/thermophysics/services
Services Materials and Applications Materials : Metals, Ceramics & Glass, Polymers, Inorganics & Organics with solid, viscoelastic or liquid material properties as well as evolved gas analysis Applica
-
b-Part
- /en/research-topics/capturing-experience/projects/translate-to-english-b-part
b-Part Building Pervasive Participation The b-Part project investigated novel concepts and solutions for citizen e-participation utilizing latest mobile device technology and appliances embedded in to